ECCN
Not legal advice. Tariffkit is a free research tool. It quotes HTS rate text and ECCN control text as published by the official sources linked here. It does not classify an item, does not apply rulings, and does not calculate duty. Verify the cited release with those sources and with counsel before you rely on it.
1A007
1A007 Equipment and devices, “specially designed” to initiate charges and devices containing “energetic materials,” by electrical means, as follows (see List of Items Controlled).
- Category
- Category 1—Special Materials and Related Equipment, Chemicals, “Microorganisms,” and “Toxins”
- Product group
- A. “End Items”, “Equipment”, “Accessories”, “Attachments”, “Parts”, “Components”and “Systems”
Reason for Control
- NS
- NP
- AT
Official text
License Requirements
Reason for Control:
NS, NP, AT
Control(s) Country chart (see supp. No. 1 to part 738)
- NS applies to entire entry NS Column 2
- NP applies to 1A007.b, as well as 1A007.a when the detonator firing set meets or exceeds the parameters of 3A229 NP Column 1
- AT applies to entire entry AT Column 1
List Based License Exceptions (See Part 740 for a Description of All License Exceptions)
LVS: N/A
GBS: N/A
List of Items Controlled
Related Controls: High explosives and related equipment “specially designed” for military use are “subject to the ITAR” (see 22 CFR parts 120 through 130). This entry does not control detonators using only primary explosives, such as lead azide. See also ECCNs 0A604, 3A229, and 3A232. See 1E001 for “development” and “production” technology controls, and 1E201 for “use” technology controls.
Related Definitions: N/A
Items:
a. Explosive detonator firing sets designed to drive explosive detonators specified by 1A007.b;
b. Electrically driven explosive detonators as follows:
b.1. Exploding bridge (EB);
b.2. Exploding bridge wire (EBW);
b.3. Slapper;
b.4. Exploding foil initiators (EFI).
Technical Notes:
1. The word initiator or igniter is sometimes used in place of the word detonator.
2. For the purposes of 1A007.b, the detonators of concern all utilize a small electrical conductor (bridge, bridge wire, or foil) that explosively vaporizes when a fast, high-current electrical pulse is passed through it. In non slapper types, the exploding conductor starts a chemical detonation in a contacting high explosive material such as PETN (pentaerythritoltetranitrate). In slapper detonators, the explosive vaporization of the electrical conductor drives a flyer or slapper across a gap, and the impact of the slapper on an explosive starts a chemical detonation.
The slapper in some designs is driven by magnetic force. The term exploding foil detonator may refer to either an EB or a slapper-type detonator.
ecfr-15cfr774-supp1-2026-08-28 · effective 2026-08-28
Issue date 2026-08-28. Amendment date 2026-08-28.
- eCFR Commerce Control List (15 CFR 774, Supplement No. 1)www.ecfr.gov
- eCFR versioner XML captured at ingestwww.ecfr.gov
This page quotes the loaded release. A shareable report freezes this text.
Was this helpful?