Not legal advice. Tariffkit is a free research tool. It quotes HTS rate text and ECCN control text as published by the official sources linked here. It does not classify an item, does not apply rulings, and does not calculate duty. Verify the cited release with those sources and with counsel before you rely on it.
2B004
2B004 Hot “isostatic presses” having all of the characteristics described in the List of Items Controlled, and “specially designed” “components” and “accessories” therefor.
- Category
- Category 2—Materials Processing
- Product group
- B. “Test”, “Inspection” and “Production Equipment”
Reason for Control
Reason for Control: NS, MT NP, AT
Official text
License Requirements
Reason for Control:
NS, MT NP, AT
Control(s) Country chart (see supp. No. 1 to part 738)
- NS applies to entire entry NS Column 2
- MT applies to entire entry MT Column 1
- NP applies to entire entry, except 2B004.b.3 and presses with maximum working pressures below 69 MPa NP Column 1
- AT applies to entire entry AT Column 1
List Based License Exceptions (See Part 740 for a Description of All License Exceptions)
LVS: N/A
GBS: N/A
List of Items Controlled
Related Controls: (1) See ECCN 2D001 for software for items controlled under this entry. (2) See ECCNs 2E001 (“development”), 2E002 (“production”), and 2E101 (“use”) for technology for items controlled under this entry. (3) For “specially designed” dies, molds and tooling, see ECCNs 0B501, 0B602, 0B606, 1B003, 9B004, and 9B009. (4) For additional controls on dies, molds and tooling, see ECCNs 1B101.d, 2B104 and 2B204. (5) Also see ECCNs 2B117 and 2B999.a.
Related Definitions: N/A
Items:
a. A controlled thermal environment within the closed cavity and possessing a chamber cavity with an inside diameter of 406 mm or more; and
b. Having any of the following:
b.1. A maximum working pressure exceeding 207 MPa;
b.2. A controlled thermal environment exceeding 1,773 K (1,500 °C); or
b.3. A facility for hydrocarbon impregnation and removal of resultant gaseous degradation products.
Technical Note:
For the purposes of 2B004, the inside chamber dimension is that of the chamber in which both the working temperature and the working pressure are achieved and does not include fixtures.
That dimension will be the smaller of either the inside diameter of the pressure chamber or the inside diameter of the insulated furnace chamber, depending on which of the two chambers is located inside the other.
ecfr-15cfr774-supp1-2026-08-28 · effective 2026-08-28
Issue date 2026-08-28. Amendment date 2026-08-28.
- eCFR Commerce Control List (15 CFR 774, Supplement No. 1)www.ecfr.gov
- eCFR versioner XML captured at ingestwww.ecfr.gov
This page quotes the loaded release. A shareable report freezes this text.
Was this helpful?
A short note about this page. Not shown on the site.