Tariffkit

ECCN

Not legal advice. Tariffkit is a free research tool. It quotes HTS rate text and ECCN control text as published by the official sources linked here. It does not classify an item, does not apply rulings, and does not calculate duty. Verify the cited release with those sources and with counsel before you rely on it.

2B351

2B351 Toxic gas monitors and monitoring systems, and their dedicated detecting “parts” and “components” (i.e., detectors, sensor devices, and replaceable sensor cartridges), as follows, except those systems and detectors controlled by ECCN 1A004.c (see List of Items Controlled).

Category
Category 2—Materials Processing
Product group
B. “Test”, “Inspection” and “Production Equipment”

Reason for Control

  • CB
  • AT

Official text

License Requirements

Reason for Control:

CB, AT

Control(s) Country Chart (see Supp. No. 1 to part 738)

  • CB applies to entire entry CB Column 2.
  • AT applies to entire entry AT Column 1.

List Based License Exceptions (See Part 740 for a Description of All License Exceptions)

LVS: N/A

GBS: N/A

List of Items Controlled

Related Controls: See ECCN 2D351 for “software” for toxic gas monitors and monitoring systems, and their dedicated detecting “parts” and “components,” controlled by this ECCN. Also see ECCN 1A004, which controls chemical detection systems and “specially designed” “parts” and “components” therefor that are “specially designed” or modified for detection or identification of chemical warfare agents, but not “specially designed” for military use, and ECCN 1A995, which controls certain detection equipment, “parts” and “components” not controlled by ECCN 1A004 or by this ECCN.

Related Definitions: (1) For the purposes of this entry, the term “dedicated” means committed entirely to a single purpose or device. (2) For the purposes of this entry, the term “continuous operation” describes the capability of the equipment to operate on line without human intervention. The intent of this entry is to control toxic gas monitors and monitoring systems capable of collection and detection of samples in environments such as chemical plants, rather than those used for batch-mode operation in laboratories.

Items:

a. Designed for continuous operation and usable for the detection of chemical warfare agents or precursor chemicals controlled by 1C350 'minimum detection limit' of 0.3 mg/m 3; or

b. Designed for the detection of cholinesterase-inhibiting activity.

Technical note:

The 'minimum detection limit' of toxic gas monitors or monitoring systems is the lowest detectable concentration of the analyte required to produce a signal greater than three times the standard deviation of the toxic gas monitor's or monitoring system's signal when measuring a blank sample. In the case of toxic gas monitors or monitoring systems having a deadband or programmed zero suppression, the 'minimum detection limit' is the lowest detectable concentration required to produce a reading.

ecfr-15cfr774-supp1-2026-08-28 · effective 2026-08-28

Issue date 2026-08-28. Amendment date 2026-08-28.

This page quotes the loaded release. A shareable report freezes this text.

Back to search

Was this helpful?

A short note about this page. Not shown on the site.

Free research lookup of official HTS and ECCN text.