ECCN
Not legal advice. Tariffkit is a free research tool. It quotes HTS rate text and ECCN control text as published by the official sources linked here. It does not classify an item, does not apply rulings, and does not calculate duty. Verify the cited release with those sources and with counsel before you rely on it.
6E993
6E993 Other “technology”, not controlled by 6E003, as follows (see List of Items Controlled).
- Category
- Category 6—Sensors and Lasers
- Product group
- E. “Technology”
Reason for Control
- RS
- AT
Official text
License Requirements
Reason for Control:
RS, AT
Control(s) Country Chart (See Supp. No. 1 to part 738)
- RS applies to 6E993.e RS Column 1
- AT applies to entire entry AT Column 1
List Based License Exceptions (See Part 740 for a description of all license exceptions)
TSR: N/A
List of Items Controlled
Related Controls: N/A
Related Definitions: N/A
Items: a. Optical fabrication technologies for serially producing optical “parts” and “components” at a rate exceeding 10 m 2 of surface area per year on any single spindle and having all of the following:
a.1. Area exceeding 1 m 2; and
a.2. Surface figure exceeding λ/10 (rms) at the designed wavelength;
b. “Technology” for optical filters with a bandwidth equal to or less than 10 nm, a field of view (FOV) exceeding 40° and a resolution exceeding 0.75 line pairs per milliradian;
c. “Technology” for the “development” or “production” of cameras controlled by 6A993;
d. “Technology” “required” for the “development” or “production” of non-triaxial fluxgate “magnetometers” or non-triaxial fluxgate “magnetometer” systems, having any of the following:
d.1. ‘Sensitivity’ lower (better) than 0.05 nT (rms) per square root Hz at frequencies of less than 1 Hz; or
d.2. ‘Sensitivity’ lower (better) than 1 × 10−3 nT (rms) per square root Hz at frequencies of 1 Hz or more.
e. “Technology” “required” for the “development” or “production” of infrared up-conversion devices having all of the following:
e.1. A response in the wavelength range exceeding 700 nm but not exceeding 1500 nm; and
e.2. A combination of an infrared photodetector, light emitting diode (OLED), and nanocrystal to convert infrared light into visible light.
Technical Note:
For the purposes of 6E993, ‘sensitivity’ (or noise level) is the root mean square of the device-limited noise floor which is the lowest signal that can be measured.
ecfr-15cfr774-supp1-2026-08-28 · effective 2026-08-28
Issue date 2026-08-28. Amendment date 2026-08-28.
- eCFR Commerce Control List (15 CFR 774, Supplement No. 1)www.ecfr.gov
- eCFR versioner XML captured at ingestwww.ecfr.gov
This page quotes the loaded release. A shareable report freezes this text.
Was this helpful?